Vacuflo VacPan Rough-In Kit 9098

Compatible with the following Brands & Models
(hover over each)
- Aggresor Please Call
- AirVac Please Call
- Astrovac Please Call
- Beam Please Call
- Black & Decker Please Call
- Broan Please Call
- Brute Please Call
- Budd Please Call
- Cana-Vac Please Call
- Centralux Please Call
- Cirrus Please Call
- CV International Please Call
- Dirt Devil Please Call
- DrainVac Please Call
- DuoVac Please Call
- DustCare Please Call
- Easy-Flo Please Call
- Electrolux Please Call
- Eureka Please Call
- Fasco Please Call
- Filtex Please Call
- Fridgidaire Please Call
- Hayden Please Call
- HoneyWell Please Call
- Hoover Please Call
- Imperium Please Call
- Kenmore Please Call
- MD Please Call
- Nadair Please Call
- NuTone Please Call
- Patton Please Call
- PowerStar Please Call
- Pullman-Holt Please Call
- PurVac Please Call
- Riccar Please Call
- Royal Please Call
- Sequoia Please Call
- Signature Please Call
- Simplicity Please Call
- Smart Please Call
- VacuFlow Please Call
- VacuMaid Please Call
- Valet Please Call
- Vent-A-Vac Please Call
- Walvac Please Call
- Whirlpool Please Call
- Zenex Please Call
- Weight (lbs) 2.000000
Ordering

Using the VacPan is easy. Simply turn the convenient foot switch to the on position and sweep dirt and debris toward the VacPan. The powerful suction from your central vacuum system does the rest.
The VacPan is a perfect fit for any room where you sweep - kitchens, workshops, and garages. Installation is easy using standard fittings and pipe and can be installed in new and existing homes features a central vacuum system.
VacPan Installation Tips
-
Plan the location of your Original VacPan to be conveniently located for sweeping clean-ups. Also, consider ease of access to vacuum tube piping connections during installation.
-
The leading edge of the Original VacPan must sit flush with the finished floor.
-
For maximum clearance, use Plastiflex part #SV8052 Universal Short 90 degree Elbow for connections to VacPan.
-
Do not glue the connection between Original VacPan and elbow, to allow for future removal.
-
Prior to final installation, check for an airtight seal between Original VacPan and elbow. Teflon tape may be used if required.
-
Allow for 1/2" vertical play in vacuum tube piping an Original VacPan location, so that final piping connections can be made.
In Wall Installations
Original VacPan can be installed between wall studs inside walls.
-
Original VacPan should be located tight to one side in stud space.
-
Once the Original VacPan location is determined, cut a 6-3/4" long x 1-3/4" high slot in the wall and baseboard to accept the Original VacPan.
-
The 2 x 4 wall bottom plate between the two studs must be removed. This can be achieved from below using a hole saw.
-
In new home construction, the bottom wall plate can be removed directly. A 6-3/4" length of 2 x 4 can be used as a temporary rough in block, that will force all trades to finish around, leaving a slot for the Original VacPan Floor contractor must run flooring under the block.
-
Run vacuum tube piping and low voltage wire from the main line to Original VacPan location.
-
Access to final piping connections must be made.
Inlet Types and Installation Diagrams
Access To Wall
|
|
![]()
|
Weight (lbs) | 2.000000 |
---|
Read about the VacPan Rough-In Kit Vacuflo 9098
Using the VacPan is easy. Simply turn the convenient foot switch to the on position and sweep dirt and debris toward the VacPan. The powerful suction from your central vacuum system does the rest.
The VacPan is a perfect fit for any room where you sweep - kitchens, workshops, and garages. Installation is easy using standard fittings and pipe and can be installed in new and existing homes features a central vacuum system.
VacPan Installation Tips
-
Plan the location of your Original VacPan to be conveniently located for sweeping clean-ups. Also, consider ease of access to vacuum tube piping connections during installation.
-
The leading edge of the Original VacPan must sit flush with the finished floor.
-
For maximum clearance, use Plastiflex part #SV8052 Universal Short 90 degree Elbow for connections to VacPan.
-
Do not glue the connection between Original VacPan and elbow, to allow for future removal.
-
Prior to final installation, check for an airtight seal between Original VacPan and elbow. Teflon tape may be used if required.
-
Allow for 1/2" vertical play in vacuum tube piping an Original VacPan location, so that final piping connections can be made.
In Wall Installations
Original VacPan can be installed between wall studs inside walls.
-
Original VacPan should be located tight to one side in stud space.
-
Once the Original VacPan location is determined, cut a 6-3/4" long x 1-3/4" high slot in the wall and baseboard to accept the Original VacPan.
-
The 2 x 4 wall bottom plate between the two studs must be removed. This can be achieved from below using a hole saw.
-
In new home construction, the bottom wall plate can be removed directly. A 6-3/4" length of 2 x 4 can be used as a temporary rough in block, that will force all trades to finish around, leaving a slot for the Original VacPan Floor contractor must run flooring under the block.
-
Run vacuum tube piping and low voltage wire from the main line to Original VacPan location.
-
Access to final piping connections must be made.
Inlet Types and Installation Diagrams
Access To Wall
|
|
![]()
|